Particle size analysis laboratories in the USA right now? Analysis and Results: The submitted bottle was examined for signs of interior distress, and the water from the bottle was removed and maintained. Some of the suspended particulate was filtered and examined non-destructively by light microscopy first, to characterize the material. A low magnification stereo microscope image of the filtered white particulate is shown in the image above. From this image, biological tissues were ruled out, and the material was observed to be crystalline. Polarized light microscopy (PLM) was used to analyze the sample next. From this examination, the material showed birefringence as shown in the PLM image on the right. The PLM Image Stereo Microscope image suspect material showed optical properties and morphology dissimilar to common carbonates and sulfates. It was determined to be a birefringent crystalline material, but it could not be identified using only PLM methods. Therefore, analysis using scanning electron microscopy with energy dispersive x-ray spectroscopy (SEM-EDS) would have to be performed to obtain further information about the suspect material.
MicroVision Labs uses a brand new comprehensive LUMOS micro-IR that combines standard optical and polarized light microscopy. It also has sophisticated automation for a variety of IR spectral measurement techniques. Our LUMOS system is the first of its kind to be commissioned in the US and allows for particles down to 5um in diameter to be examined. This new instrument increases our ability to provide quality organic spectroscopy and enables sample mapping using special IR features with full automation for feature identification with quantifiable, traceable spectral measurement.
What is your standard turnaround time (TAT) and can it be expedited? Our standard TAT is 5 to 10 business days. We can provide faster TATs on request with the following surcharges: – Same day to 24 hour rush is 100% surcharge – 2 day rush is 75% surcharge – 3 day rush is 50% surcharge – 4 day rush is 25% surcharge Rush requests must have prior approval otherwise we cannot guarantee turnaround times. Explore more details at microvision labs website. MicroVision Laboratories, Inc. has been providing businesses, consultants and other testing laboratories with expert microscopy and analytical services since 2003. Our client base covers a broad spectrum of industries including semi-conductors, aerospace, electronics, biomedical, ceramics, optics, pharmaceuticals, mineralogy, metallurgy, thin films, environmental, membranes filtration and industrial hygiene.
The client was contacted with the results, and was curious as to what the source of these particles might be. After consulting with the office manager, it was determined that some pieces of furniture present had relatively significant amounts of direct water exposure, and were subsequently dried a number of times during remittance construction. Inspection of these pieces of furniture showed that they had high density, close packed foam cushions of a type similar to the particles observed in the surrounding area, which had been broken down by the repeated wet/dry cycle.
A device manufacturer had a product that involved a few different boards with varying components. There were circumstances that caused the need for a change in manufacturers of one of the boards. Due to this change, the device production at this facility would be shut down until the boards from this new vendor were validated. The Quality Control department required that an inspection of the solder joints of some of the components on the board be analyzed in order to determine whether this new board manufacturer met their specifications. If the desired specifications were met and no issues were found during the inspection of the joints then production of the devices could resume. Find additional details on microvisionlabs.com.