Pill stamp press manufacturer today: The connection between the wall and the floor and the ceiling should be in a concave arc shape, without gaps, leaving no dead corners. The aseptic operation room should have a unidirectional air device for air sterilization filtration, a super-clean workbench with a cleanliness of 100 or the same level, indoor temperature control of 18-26 ℃, and relative humidity of 45%-65%. The buffer room and the operating room should be equipped with UV lamps or other appropriate disinfection devices that can achieve the effect of air disinfection. The static pressure difference between adjacent rooms with different air cleanliness levels should be greater than 5Pa, and the static pressure difference between the clean room (area) and the outdoor atmosphere should be greater than 10Pa. The lighting in the aseptic room should be embedded in the ceiling, the indoor light should be evenly distributed, and the illuminance is not less than 300lx. Discover additional information at tablet press dies.
The material of the equipment is safe, stable, heat-resistant, and corrosion-resistant. Completely enclosed during production, it will not cause pollution to the outside environment, nor will it be contaminated by the outside environment. The equipment should be easy to clean and preferably have a self-cleaning function. Pharmaceutical equipment has an automatic control system that can systematically control, count, and reduce labor costs. Some drugs have special properties, so it is best for pharmaceutical equipment to have dust-proof, waterproof, and explosion-proof functions. For safety reasons, there should be a one click pause automatic protection equipment.
The filling speed of the capsule filling machine is fast, and the size difference of the capsule filling machine is small. It integrates the powder capsule shell finishing, capsule cap finishing and capsule package, which is compact and convenient. In addition, the capsule filling machine has many advantages, such as fast arrangement speed, high efficiency, simple operation, convenient maintenance and low power consumption. It is the preferred capsule filling (filling) machine for pharmaceutical factories, health product factories, hospital preparation rooms, etc
As industries and research labs continue to embrace clean rooms as essential components of their operations, it’s crucial for professionals to understand the ideal cleanroom humidity levels within these controlled environments. Clean rooms, also known as sterile rooms or anti-static rooms, are designed to minimize contamination from dust, debris, and other environmental factors. Maintaining optimal humidity levels is an integral part of ensuring the cleanliness and functionality of clean rooms. In this blog post, we’ll discuss the normal humidity range for clean rooms and how to maintain them effectively.
The plane and space design of the clean laboratory will arrange the clean experimental area and personnel purification, equipment and material purification and other auxiliary rooms in different areas. At the same time, the comprehensive coordination effects of various technical facilities, such as experimental operation, process equipment installation and maintenance, air distribution type, pipeline layout and purified air conditioning system, are considered.
The detection of air volume and wind speed must be carried out first, and all effects of purified air conditioning must be obtained under the designed air volume and wind speed. Before air volume detection, it is necessary to check whether the fan operates normally, whether all components in the system are installed correctly and whether there are obstacles (such as whether the filter is blocked or blocked). All valves should be fixed at a certain opening position, and the size of the measured air outlet and air duct must be measured. For the turbulent flow clean room, the air supply volume shall be determined by the air outlet method or air duct method. See Item 6, 7 and 8 respectively. For the air outlet without filter, the method in Appendix I of the current national standard code for construction and acceptance of ventilation and air conditioning engineering (gbj243) can be implemented.
Cleanroom pharma factory today: Obstacles such as work desks in the clean room will have eddy currents at the junctions, and the cleanliness will be relatively poor near them. Drilling air return holes on the work desks will minimize eddy currents; assembly Whether the selection of materials is appropriate and whether the equipment layout is perfect are also important factors for whether the airflow becomes a vortex phenomenon. The above introduction is related to clean room and airflow influencing factors.
A clean room refers to the removal of particulates, harmful air, bacteria and other pollutants in the air within a certain space, and the indoor temperature, cleanliness, indoor pressure, airflow speed and airflow distribution, noise vibration and lighting, Static control is within a certain demand range, and a specially designed room is given. That is to say, no matter how the external air conditions change, the interior can maintain the characteristics of cleanliness, temperature, humidity and pressure that were originally set. The main function of the clean room is to control the cleanliness and temperature and humidity of the atmosphere that the product comes into contact with, so that the product can be produced and manufactured in a good environmental space. We call such a space a clean room.
With our vast experience in handing national and international Pharma/Laboratory Projects.we ensure that professional integration of project will have plenty of benefits. The company has complete infrastructure and a team of experienced personnel to managing these fields more professionally. When it comes to your cleanroom certification,we have the qualifications and experience to deliver a comprehensive validation service off facilities to he requirements of all the current standard and guidelines globally.And our cleanroom are CE Market to show they meet the requirements of local country directives. Discover additional details at https://www.sz-pharma.com/.
Laboratory furniture, laboratory test equipment, including fume hood, experimental cabinet, storage cabinet, etc. According to the material classification, including all steel, all wood, steel wood, aluminum wood, stainless steel, PP and other types. For biology, medicine, coating laboratory and clean room, thorough cleaning and disinfection is the first function to be considered, which requires the laboratory furniture to be easy to clean, disinfect and keep clean for a long time.